General

WARNING! Never use a machine that has
!
faulty safety equipment! If your machine
fails any of these checks contact your
service agent to get it repaired.
This section describes the machine´s safety equipment, its
purpose, and how checks and maintenance should be carried
out to ensure that it operates correctly.
Power switch
The power switch should be used to start and stop the
machine.
Checking the power switch
Start the machine, release the power switch and check
that the motor and the drill bit stop.
A defective power switch should be replaced by an
authorized service workshop.
6 –
English
MACHINE´S SAFETY EQUIPMENT
Ground fault circuit interrupter
Ground fault circuit interrupters are for protection in case an
electrical fault should occur.
The LED indicates that the ground fault circuit interrupter is on
and that the machine can be switched on. If the LED is not
on, push the RESET button (green).
Check the ground fault circuit interrupter
Connect the machine to the socket. Push the RESET
button (green) and the red LED lights up.
Start the machine by pressing the power switch.
Push the TEST button (blue).
The ground fault circuit interrupter should trip and the
machine switch off instantly. If not, contact your dealer.
Reset with the RESET button (green).