Recommended Fuels; Technical Data; Re-Fuelling - Stanley Aoife Installation And Operating Instructions Manual

Solid fuel nb stove
Table of Contents

Advertisement

3. Window wash air control, slide to the right to open
and to the left to close. See Fig.9.
When burning coal open window wash and primary
air controls, keep the secondary air control closed.
Regulate the burn rate using the spin valve.
When burning wood open the secondary air and
window wash, regulate the burn rate using the sec-
ondary air control. If necessary open the spin valve
a little, approximately a half turn.
When buring anthracite open the primary air control
only, both secondary air control and window wash
must remain closed when burning this fuel.

RECOMMENDED FUELS

All fuels should be stored under cover and kept
as dry as possible prior to use.
This appliance has been tested using seasoned
wood logs and manufactured briquetted smokeless
fuel (Ancit) for closed appliances, sized between
20g and 140g. Other fuels are commercially avail-
able and may give similar results. Wood logs up to
300mm long are suitable. All fuels should be stored
under cover and kept as dry as possible prior to use.
Do not use fuels with a Petro-coke ingredient as this
may cause the grate to overheat, causing damage.
Reduced outputs will result when fuels of lower
calorific values are used. Never use gasoline or
gasoline type lantern fuel, kerosene, charcoal lighter
fluid or similar liquids to start or freshen up a fire in
this heater. Keep all such liquid well away from the
heater at all times. Operate the stove only with the
fuelling door closed except for re-fuelling.
Fig.9
This stove has obtained HETAS Ltd approval as an
'intermittent' operating appliance for burning Natural
wood logs and manufactured smokeless fuels as
detailed in recommended fuels below..
Approval does not cover the use of other fuels either
alone or mixed with the recommended fuels listed,
nor does it cover instructions for the use of other
fuels.
AOIFE - TECHNICAL DATA
Parameter
Max Heat Output
Nominal Heat Output
Output to Room
Typical Refuel Interval To
Achieve Nominal Outputs
Mean Flue Gas Temp.
Gross Weight
Flue Outlet Diameter
Wood Log Size

RE-FUELLING

Riddle the fire by connecting the grate operating tool
onto the rocker connection located at the bottom
front of the stove, then gently pull and push the rock-
er arm until all dead ash has fallen through into the
ashpan. Before opening the door, open the spin
valve by turning it anti-clockwise, as this will help to
eliminate any smoke or fly ash resident in the com-
bustion chamber. Add fuel to fire, close fire door and
re-set spin valve to required setting. (See Fig.10)
Fig.10
8
HETAS
NON BOILER
Fuel Coal Wood
(kW)
7.3
6.6
(kW)
7.3
6.6
(kW)
7.3
6.6
1.00
.75
(h)
o
(
C)
311
343
(kg)
105
(mm)
125
(mm)
N/A
300

Hide quick links: