Read/Write Registers; Group:fundamental Parameters #1 - Toshiba TOSVERT-130 G3 Interface Manual

High performance transistor inverter true torque control drive series
Hide thumbs Also See for TOSVERT-130 G3:
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc

9.3 Read/Write Registers

9.3.1 GROUP:FUNDAMENTAL PARAMETERS #1

Register
Function / Title
26
MAXIMUM OUTPUT
FREQUENCY
27
BASE FREQUENCY #1
28
BASE FREQUENCY
VOLTAGE SELECT
29
MAXIMUM OUTPUT
VOLTAGE #1
2A
REVERSE OPERATION
DISABLE SELECT
2B
UPPER LIMIT
FREQUENCY
2C
LOWER LIMIT
FREQUENCY
2D
VOLTS PER HERTZ
PATTERN
2E
1, 2
VOLTAGE BOOST
#1
2F
ACCELERATION TIME
#1
30
DECELERATION TIME
#1
31
ACC/DEC PATTERN #1
SELECTION
32
ACCEL/DECEL PATTERN
ADJUST LOW
33
ACCEL/DECEL PATTERN
ADJUST HIGH
Note 1: Register data = (desired setting x 5 + 3), converted to hexadecimal
Bank
Mask
0BB8 ∼ 9C40 (30.00∼400.00)
0 / 1
FFFF
(T)
09C4 ∼ 9C40 (25.00∼400.00)
0 / 1
FFFF
0 / 1
0030
0000: Input voltage level
(T)
0020: Automatic setting
0030: Stationary setting
0000 ∼ 0258 (0 ∼ 600)
0 / 1
FFFF
0 / 1
0020
0000: Reverse allowed
0020: Reverse not allowed
0 / 1
FFFF
0000 ~ Fmax
0000 ∼ UL, Fmax
0 / 1
FFFF
0 / 1
000F
0000: Constant torque
(T)
0001: Variable torque
0002: Auto. torque boost
0006: #3 w/ auto. energy savings (4)
000A: Vector control
000E: #5 w/ auto. energy savings (6)
0000 ∼ 012C (0.0 ∼ 30.0)
0 / 1
FFFF
0001 ∼ EA60 (0.01~ 600.00)
0 / 1
FFFF
0001 ∼ EA60 (0.1~ 6000.0)
0001 ∼ EA60 (0.01~ 600.00)
0 / 1
FFFF
0001 ∼ EA60 (0.1~ 6000.0)
0 / 1
0030
0000: Linear
0010: Self-adjusting
0020: S-Pattern #1
0030: S-Pattern #2
0003 ~ 00FD (0 ∼ 50)
0 / 1
00FF
0003 ~ 00FD (0 ∼ 50)
0 / 1
00FF
27
Adjustment Range
(0)
(1)
(2)
(0)
(1)
(1)
(2)
(3)
(5)
(0)
(1)
(2)
(3)
(Note 1)
(Note 1)
Multiplier
0.01
0.01
1
0.01
0.01
0.1
0.01
0.1
0.01
0.1
1
1

Advertisement

Table of Contents
loading

Table of Contents