Table 6: Output Terminal Selections (RCH, LOW, FL, OUT relay contacts)
Setting
Data
Value
(Hex)
0
0000
Lower limit frequency
1
0100
/Lower limit frequency
2
0200
Upper limit frequency
3
0300
/Upper limit frequency
4
0400
Low speed signal
5
0500
/Low speed signal
6
0600
Accel/decel complete
7
0700
/Accel/decel complete
8
0800
Selected speed reach signal
9
0900
/Selected speed reach signal
10
0A00
Fault
11
0B00
/Fault
12
0C00
Fault other than earth fault or
load-end overcurrent
13
0D00
/Fault other than earth fault or
load-end overcurrent
14
95B5
Overcurrent pre-alarm
15
9DB5
/Overcurrent pre-alarm
16
85C5
Inverter overload pre-alarm
17
8DC5
/Inverter overload pre-alarm
18
95C5
Motor overload pre-alarm
19
9DC5
/Motor overload pre-alarm
20
D5C5
Overheat pre-alarm
21
DDC5
/Overheat pre-alarm
22
A5B4
Overvoltage pre-alarm
23
ADB4
/Overvoltage pre-alarm
24
E5B4
Undervoltage alarm
25
EDB4
/Undervoltage alarm
26
85B5
Undercurrent alarm
27
8DB5
/Undercurrent alarm
28
85D1
Overtorque alarm
29
8DD1
/Overtorque alarm
30
E5BB
Braking resistor OL pre-alarm
31
EDBB
/Braking resistor OL pre-alarm
Function
Setting
Value
32
Data
(Hex)
32
C5B7
Executing emergency off
33
CDB7
/Executing emergency off
34
B5BB
Executing retry
35
BDBB
/Executing retry
36
D5CF
Pattern run switching output
37
DDCF
/Pattern run switching output
38
D5D8
PID deviation limit
39
DDD8
/PID deviation limit
40
C5BB
Run/stop
41
CDBB
/Run/stop
42
1400
Severe fault (armature short, load-
end short, open phase, output
error, earth fault)
43
1500
/Severe fault (armature short,
load-end short, open phase,
output error, earth fault)
44
1600
Non-severe fault (overload,
overcurrent, overvoltage)
45
1700
/Non-severe fault (overload,
overcurrent, overvoltage)
46
E5D8
Commercial power / inverter
sw itching output #1
47
EDD8
/Commercial power / inverter
switching output #1
48
F5D8
Commercial power / inverter
switching output #2
49
FDD8
/Commercial power / inverter
switching output #2
50
85C0
Fan ON/OFF
51
8DC0
/Fan ON/OFF
52
F5B6
Executing JOG
53
FDB6
/Executing JOG
54
1800
Local/remote operation
55
1900
/Local/remote operation
56
A5D1
Cumulative timer alarm
57
ADD1
/Cumulative timer alarm
58
1A00
Communication error alarm
59
1B00
/Communication error alarm
60
A5B6
F/R
61
ADB6
/F/R
62
1E00
Run preparation complete
63
1F00
/Run preparation complete
Function