Gas Control Valve; Pilot Burner Adjustment; Troubleshooting - Montigo H38DF-PRC Installation, Operation & Maintenance Manual

Indoor panorama gas fireplace
Table of Contents

Advertisement

Gas Control Valve

Pilot Adjustment Screw
Inlet
Pressure
Manifold Pressure
Test Connection
Figure 33. Sit Nova 820 gas valve.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw. (See figure 33.)
2. Adjust pilot screw to provide properly sized flame as shown in
figure 34).
3. After installing or servicing, leak test with a soap solution with
main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.
Figure 34. Pilot Burner.

Troubleshooting

The following is a troubleshooting chart of possible problems:
PROBLEM
Noisy Pilot Flame
Locate pilot adjustement screw on
gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won't ignite
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram figure 33.
Main burner will
1. Check wiring (see figure 33).
not light
2. Check wall switch for proper con-
nection.
Part No. XG0211 - 080510
Maintenance
Power
Generator
Wall Switch
CORRECTIVE ACTION
H(L)38DF-PRC Indoor Panorama Gas Fireplace
Troubleshooting
If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
Technician.
All spare parts, optional fans, and optional trim finishes are available
from your local dealer or the manufacturer.