Montigo H38DF-PRC Installation, Operation & Maintenance Manual page 13

Indoor panorama gas fireplace
Table of Contents

Advertisement

Section 3-3-2:
VENTING COMPONENTS
The following components and associated Montigo part num-
bers are available for installation of a Wall Mounted Termination.
Use only Montigo Vent Components. Use of non-Montigo parts
will void the warranty and may impede operation of the fireplace.
A - Termination
B - Stucco Kits
C - Flex Sections
D - Rigid
Sections
E - Elbows
Connection and installation of the vent components should
adhere to the following guidelines:
Use any combination of rigid and Flex pipe as required.
Flex sections may be stretched up to 50% of their total length
(e.g. a 24" section maybe stretched to 36").
Connect all vent sections using a minimum of three sheet metal
screws on the outer pipe flue..
Ensure the pipe ends male to female slide in a minimum of 1
1/2" of overlap.
Ensure all runs are supported with a minimum of 3 supports
per 10' of venting.
When hanging/ supporting venting, ensure that 1" clearance
is maintained on sides and bottom of vent runs and 2" above
horizontal vent runs to any combustible material.
Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
Place the springs, supplied with the pipe kit, between the outer
and inner pipes to keep the pipes separate and avoid any
possible hot spots.
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
Part No. XG0211 - 080510
Installation
PTO-3 (3" Length)
PTO-3F (3" Length)
PTO-4 (3" Length)
PTO-4F (3" Length)
MSR (Stucco Frame)
BSR-4 (4" Brick Frame)
BSR-6 (6" Brick Frame)
MOSR (Stucco Can)
PFL- 1 (12" f/f Section)
PFL- 18 (18" f/f Section)
PFL- 2 (24" f/f Section)
PFL- 3 (36" f/f Section)
PFL- 4 (48" f/f Section)
PFL- 6 (72" f/f Section)
PXT- 5 (5" f/f Section)
PXT-10 (10" f/f Section)
PEXT- 1 (12" m/f Section)
PXT- 20 (20" f/f Section)
PEXT- 2 (24" m/f Section)
PEXT- 3 (36" m/f Section)
PEXT- 4 (48" m/f Section)
PEXT- 6 (72" m/f Section)
PEL- 90MM (m/m 90° Elbow)
PEL- 90FF (f/f 90° Elbow)
PEL- 90FM (f/m 90° Elbow)
PEL- 45FM (f/m 45° Elbow)
H(L)38DF-PRC Indoor Panorama Gas Fireplace
When penetrating a combustible ceiling, a ceiling firestop
must be used.
Montigo recommends that all exterior corners and joints be
sealed with exterior caulking however we encourage you to
consult your Building Envelope Engineer or Waterproofing
Consultant for further recommendations.