SPX Power Xpress Installation Manual page 17

Bollard charge station
Table of Contents

Advertisement

Power Xpress™ Bollard Charge Station
Installation Guide
NOTE: All connections must be liquid-tight.
17. Feed wires into the hole in the top of the EVSE
and attach 1/2-in. liquid-tight flexible conduit
with a liquid-tight fitting.
A. 1/2-in. liquid-tight flexible conduit
B. Liquid-tight fitting
C. EVSE
Figure 21. Wires Inserted into EVSE and
Conduit Installed
18. Cut wires to length.
EL-50600-17 Rev. A
19. Strip wires and wire them into the EVSE. Refer
A
B
C
20. Install EVSE cover.
to label on inside of EVSE cover or details on
circuit board. Torque terminal screws to 10.62
± 1 in-lb (1.2 ± 0.12 Nm).
Figure 22. Wires Installed into EVSE
A. 1/2-in. liquid-tight flexible conduit
B. EVSE cover
Figure 23. EVSE Cover Installed
A
B
17