12. Position the conduit on the left side of the
bollard (opposite the open metal slot side).
B
A. Tapered EVSE guide bracket
B. 1/2-in. liquid-tight flexible conduit
Figure 17. Conduit Positioned on Left
13. Gently guide the EVSE body down through the
bollard until it rests on the top of the tapered
guide bracket.
C
A. EVSE
B. Tapered EVSE guide bracket
C. 1/2-in. liquid-tight flexible conduit
Figure 18. EVSE Resting on Bracket
16
Power Xpress™ Bollard Charge Station
14. Mark 1/2-in. liquid-tight flexible conduit for
length based on the required radius bend to
attach to the top of the EVSE.
A
A
A. Location to cut conduit
B. Precut hole in top of EVSE
C. 1/2-in. liquid-tight flexible conduit
Figure 19. Location to Cut Conduit
15. Cut 1/2-in. liquid-tight flexible conduit to
length. Do not cut wires.
16. Install approved, liquid-tight fittings to attach
1/2-in. liquid-tight flexible conduit to top of
EVSE.
A
B
A. 1/2-in. liquid-tight flexible conduit
B. Liquid-tight fitting
Figure 20. Fittings Installed
Installation Guide
B
A
B
EL-50600-17 Rev. A
C