Removing The Control Panel

Before removing the control panel insure that the
MAINS SUPPLY is switched OFF. Either remove fuse
F1 from the power supply or shut down power source
to the metal detector.
The control panel is mounted on the search head
( or remote box ) with four mounting bolts. Remove
these bolts to gain access to internal connectors.
The power supply and search head cables are wired
into 'quick disconnect' connectors. It is not
necessary to remove the wires from these connectors.
When removing the connectors be careful not to pull
on the wires, pinch the connector and pull.
Figure 19
Installing The Control Panel
When installing the control panel repeat the above
instructions in reverse order.
Note:
Care must be taken to insure that the search
head connector is fitted
correctly.
Control Panel Connections
Power Supply Connector
Search Head Connector
Cable: Belden 9261
To
Control
Panel
Shield
To Case
Ground
To
Search Head
Cable: Belden 9873
18
DSP 2 Control Panel
( Back View )
Red
Black
Orange
White
Green
Blue
Red/Blk
Blk/Wht
Org/Blk
Wht/Blk
Grn/Blk
Blu/Blk
Figure 20
White
GRN
Shield
Black
Black
YEL
Black
Red
RED
Green
Figure 21
Eprom Socket
Ground Connector
Inside Control Box
( Pull Disconnect )
PL3
24 VA
1
AGND
2
REJ
3
FAULT
4
EMU
5
RCHK
6
7V
7
DGND
8
IO 1
9
IO 2
10
RX
11
TX
12
S/H Connector
1
I/P REF 1
2
AN. GROUND
3
I/P REF 2
4
C/NC
5
OSC. REF A
6
+ 24 VDC
7
OSC. REF B