Crossover Wiring

If the twisted-pair cable is to join two ports and either both ports are labeled with an
"X" (MDI-X) or neither port is labeled with an "X" (MDI), a crossover must be
implemented in the wiring.
End A

Console Port Pin Assignments

The DB-9 console port on the front panel of the access point is used to connect to
the access point for out-of-band console configuration. The command-line
configuration program can be accessed from a terminal, or a PC running a terminal
emulation program. The pin assignments and cable wiring used to connect to the
console port are provided in the following table.
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Crossover Cable
White/Orange Stripe
Orange
White/Green Stripe
1
2
Blue
3
4
White/Blue Stripe
5
6
Green
7
8
White/Brown Stripe
Brown
1
6
Console Port Pin Assignments
1
2
3
4
5
6
7
8
5
9
End B