Configure the Devices Connected to the RVON-C Card

See the device user manual for specific configuration instructions.

Setting up a Serial Pass-Through Connection or Serial Connection

If you plan to pass data using either a Serial Pass-Through or Serial Connection you need to set the DIP switches and jumpers
to reflect which connection you want to use.
NOTE:
When making adjustments to the DIP switches and jumpers, you msut take the front card out of the Cronus.
To use the Serial Pass-Through, do the following:
Set DIP Switch 6 to the OPEN position.
1.
Set the serial protocol, either RS232 or RS485:
2.
For RS232, jumper pins 2 & 3 of J10, J11, and J12
For RS485, jumper pins 1 & 2 of J10, J11, and J12
Once you have set the correct configurations, place the RVON-C into Cronus and hook the DB-9 connector to the
3.
RVON-C backcard.
To use the Serial connection, do the following:
Set DIP Switch 6 to the CLOSED position.
1.
Set the serial protocol, either RS232 or RS485:
2.
For RS232, jumper pins 2 & 3 of J10, J11, and J12
For RS485, jumper pins 1 & 2 of J10, J11, and J12
Once you have set the correct configuration, replace the RVON-C into Cronus and hook the DB-9 connector to the
3.
RVON-C backcard.
Use Table 9, "Serial Command Table," on page 75, to configure you RVON-C card.