Electrical Specifications – 115V, 60Hz, 1 phase
U300 series dispensers with remote icemaker(s) require separate circuit and
!
disconnect for each icemaker and dispenser.
Single-sided models
U300 – dispenser 6.0 amps
U300B – dispenser 7.0 amps
U300R400A/W – dispenser 6.0 amps, icemaker 11.0 amps
U300BR400A/W – dispenser 7.0 amps, icemaker 11.0 amps
U300R800A/W – dispenser 6.0 amps, icemakers 11.0 amps each
U300BR800A/W – dispenser 7.0 amps, icemakers 11.0 amps each
Dual-sided models
UD300 – dispenser 8.0 amps
UD300R400A/W – dispenser 8.0 amps, icemaker 11.0 amps
UD300R800A/W – dispenser 8.0 amps, icemakers 11.0 amps each
Note: Each icemaker and dispenser require separate circuit with electrical disconnect within
10 feet (6m). Equipment ground required. Standard electrical – 115V, 60 Hz, 1 phase. Max. fuse
dispenser – 15 amps; each icemaker – 20 amps.
On all models with remote icemaker(s), black wire on icemaker control board
!
LINE VAC terminal must be moved to 24V terminal.
Plumbing
!
Do not reduce size of drain lines or tie drains together.
Dispenser – all models
3/4" PVC slip fit bin drain
1" PVC slip fit drain pan drain(s)
1" PVC slip fit beverage bath drain (units with beverage cooling only)
Note: Drains must be hard piped and insulated. Maintain 1/4" per foot (6mm per 304mm) min. slope
Icemaker – automatic load models only
1/4" FPT water in
1/2" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
Note: Water disconnect within 10 feet (3m) of icemaker(s) is required for automatic load units