Power Supply - THOMSON LDK 20 S Operator's Manual

Studio camera
Table of Contents

Advertisement

Power Supply

Connector Panel Right
2
1
1
Mains power supply On/Off switch
Switches the mains power supply to camera and
viewfinder on or off.
2
Mains power supply input connector
Input Voltage
for NTSC version:
for PAL version:230 Vac (+15%)
The frequency of the mains power supply must be
between 47Hz and 63Hz. The input voltage can be
selected using the mains and utility voltage switch
located behind the rear connector panel.
Mains power supply fuses
3
For 115 Line voltage:-
For 230 Line voltage:-
4
Utility outlet fuse
This fuse is for the utility outlet. Replace only with the
same type - T1A/115V or T0.4A/230V.
4-2
1
VTR
Ref
Aux
Power
CVBS
Data
Off
W arning:
This apparatus
must be earthed
4
5
Connector Panel Left
T1A/115V
Floor
VF
T0,4A/230V
Trac ker
TP
70VA
Max.
6
115 Vac (+15%)
4A Slow, 250 Vac
1.6A Slow, 250 Vac
Operator's Manual LDK 20(S) - Studio Camera
2
3
230V~T1,6A
50-60Hz
115V~T4A
Progr
Eng
Prod
Eng
Off
Prod
5
Utility outlet power indicator
Lights when power is available at the utility outlet.
Utility outlet
6
Supplies power (maximum 70W) at the mains supply
voltage and frequency. (Loading or unloading this
outlet could interrupt camera operation.)
Local / Remote switch
7
The local/remote switch behind the rear connector
panel is used to determine how the camera receives
its power. In the Local position power is supplied via
the mains power supply input connector
Remote position the camera is supplied via the Triax
cable.
2
R
E
230V
M
115V
O
T
E
Mains and Utility
Voltage Switch
7
Location of Controls and Functions
. In the