Circuit Breaker And Fuse Information - Raymarine SPX 10 Installation Manual

Spx smartpilot system
Hide thumbs Also See for SPX 10:
Table of Contents

Advertisement

28
Drive type
Type 3 drive 12 V (X30)
Type 3 drive 24 V (X30)

Circuit breaker and fuse information

Select the appropriate circuit breaker or fuse for your system using the table below as
a guide.
Drive unit
Rotary drive
Linear drive
Hydraulic pump
Hydraulic linear
I/O
CR pump solenoids
To connect the power and drive unit
Fit the power cable to the distribution panel.(We recommend using a dedicated
circuit breaker for the power cable).
Route the power cable to the SPX SmartPilot and fit it to the POWER INPUTS ter-
minal.
Connect the drive cables to the DRIVE MOTOR OUTPUTS terminal.
Connect the drive to the DRIVE CLUTCH OUTPUTS.
Motor phasing is determined during commissioning: refer to separate commissioning
guide for further information.
Cable length
up to 5m (16ft)
up to 5m (16ft)
up to 7m (23ft)
Fuse
Type 1, 12 V
25 A
Type 1,24 V
25 A
Type 2, 12 V
40 A
Type 2, 24 V
30 A
Type 3,
40 A
12V and 24V
15 A
10 A
Cable gauge
Copper area
8 AWG
10 mm
10 AWG
6 mm
8 AWG
10 mm
Thermal over-current circuit
breaker
20 A
20 A
30 A
30 A
30 A
10 A
10 A
2
2
2

Hide quick links: