• IR Emitters
• IR Blaster
IR Emitters
1
Plug the 3.5 mm connector end of one of the four
(4) IR stick-on emitters provided into an IR Out
port on the HC-250.
2
Place the stick-on emitter end over the IR
receiver on the Media Player, TV, or other target
device to drive IR signals from the HC-250 to the
target.
IR Blaster
The HC-250 is also equipped with an IR blaster
which is located just left of the front LEDs. To use the
blaster rather than an IR emitter:
1
In Composer, connect the IR Blaster of the
Controller to the IR In for the device you want to
control.
2
Test and verify that the HC-250 is positioned in
such a way that the blaster can reach the device
you want to control.
Setting Up External Storage Devices
You can store and access media from an external
storage device, for example, a network hard drive
or USB memory device, by plugging the USB drive
into the USB port and configure or scan the media in
Composer Pro.
NOTES:
(1) We support only USB drives
that are externally powered or USB sticks
(solid state). Self-powered USB drives are
not supported. (2) When using USB storage
devices on an HC-250, you can only use one
(1) partition with a 2TB maximum size. This
limitation applies to the USB storage on all
other Controllers also.
Composer Pro Driver Information
Select the Home Controller HC-250 driver in
Composer Pro and add it to your Composer project.
See the Composer Pro User Guide for details.

Troubleshooting

Factory Restore Button
CAUTION!
This action deletes the Composer
project.
To restore the HC-250 for system recovery to the
factory default image, perform the following steps:
1
Disconnect power to the HC-250.
2
Insert one end of a paper clip into the small
hole on the back of the HC-250 that is labeled
'Factory Restore.'
3
While pressing and holding the Factory Restore
button, power on the HC-250.
4
Hold the button until the Status LED blinks
Orange. This should take 5 to 7 seconds. The
Status LED will blink Orange while the restore
proces is running.
Identification Button (Identify and Network Reset)
To reset the HC-250 network settings to the default,
perform the following steps:
1
Disconnect power to the HC-250.
2
While pressing and holding the ID button on the
back of the HC-250, power on the HC-250.
3
Hold the ID button until the Data, Link and Power
LEDs are solid Blue, then immediately release the
button.
4
If during the boot sequence the Status LED stays
Orange, press and hold the Identification button
until the LED blinks Blue, and then release it.