TANDBERG Codec C90 Administrator's Manual page 34

Hide thumbs Also See for Codec C90:
Table of Contents

Advertisement

TANDBERG Codec C90 and Profiles using C90
Contents
Contents
Introduction
Introduction
The Video settings,
cont...
Video OSD InputMethod InputLanguage
The codec can be enabled for Cyrillic input characters in the GUI (Graphical User Interface). NOTE!
Requires that Video OSD inputMethod Cyrillic is set to On.
Value space: <Latin/Cyrillic>
Latin: Latin characters can be entered when using the remote control (default).
Cyrillic characters can be entered using the remote control. NOTE! Requires a TANDBERG Remote
Control TRC5 with Cyrillic fonts.
Example:
Video OSD InputMethod InputLanguage: Latin
Video OSD InputMethod Cyrillic
This configuration is used to hide or show the Cyrillic mode as menu input language in the GUI (Graphical
User Interface).
Value space: <On/Off>
On: Cyrillic mode is available as a menu input language in the GUI. This will enable the setting Video
OSD InputMethod InputLanguage.
Off: Cyrillic mode is NOT available as a menu input language in the GUI.
Example:
Video OSD InputMethod Cyrillic: Off
Video OSD Mode
The Video OSD (On Screen Display) Mode lets you define if information and icons should be displayed on
screen.
Value space: <On/Off>
On: Display the on screen menus, icons and indicators.
Off: Hide the on screen menus, icons and indicators.
Example:
Video OSD Mode: On
D14635.03—MAY 2010
Advanced config.
Advanced configuration
Advanced configuration
Password protection
Password protection
About monitors
About monitors
Audio matters
Audio matters
The Video settings,
cont...
Video OSD Output
The Video OSD (On Screen Display) Output lets you define which monitor should display the on screen
menus, information and icons. By default the OSD is sent to the monitor connected to the Video OSD
Output 1. If you cannot see the OSD on screen, then you must re-configure the OSD Output. You can
do this by entering a key sequence on the remote control, from the web interface, or by a command line
interface.
Using the TANDBERG Remote Control TRC5: Press the Disconnect key followed by: * # * # 0 x # (where x
is output 1 to 4).
Using the web interface: Open a web browser and enter the IP address of the codec. Open the Advanced
menu and navigate to Video OSD Output and select the video output.
Using a command line interface: Open a command line interface and connect to the codec (if in doubt of
how to do this, see the API Guide for the codec). Enter the command: xConfiguration Video OSD Output
[1..4] (select the OSD Output).
Value space: <1..4>
Range: Select 1 for HDMI 1 output, select 2 for DVI-I 2 output, select 3 for HDMI 3 output, or select 4
for DVI-I 4 output.
Example:
Video OSD Output: 1
Video OSD TodaysBookings
This setting can be used to display the systems bookings for today on the main OSD menu. This requires
that the system is bookable by an external booking system, like TMS (TANDBERG Management Suite).
Value space: <On/Off>
On: Displays information about this systems bookings on screen.
Off: Do not display todays bookings.
Example:
Video OSD TodaysBookings: Off
Video OSD MyContactsExpanded
Set how the local contacts will be displayed in the phone book dialog in the OSD (On Screen Display).
Value space: <On/Off>
On: The local contacts in the phone book will be shown in the top level of the phonebook dialog.
Off: The local contacts will be placed in a separate folder called MyContacts in the phonebook dialog.
Example:
Video OSD MyContactsExpanded: Off
34
Administrator guide
Appendices
Appendices
Contact us
Contact us
www.tandberg.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profiles c90

Table of Contents