Replacing The Mains Supply Cable - Baumatic BO910SS User Manual

60 cm built in multifunction self cleaning pyrolytic double oven
Table of Contents

Advertisement

o IMPORTANT: The appliance must NOT be connected to the
mains supply by means of a 13A plug and socket.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the oven is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.

Replacing the mains supply cable

o If the mains supply cable is damaged, then it must be replaced
with a suitable replacement.
o The mains supply cable should be replaced in accordance with
the following instructions:
o Switch the appliance off at the socket.
o Open the terminal block on the back of the oven.
o Unscrew the terminal screws fixing the cable.
o Replace the cable with one of the same length and in accordance
with the specification.
o The "green-yellow" earth wire must be connected to the terminal
marked
neutral wires.
o The "blue" neutral wire must be connected to the terminal
marked with letter (N) - the live wire must be connected to the
terminal marked with letter (L).
. It must be about 10 mm longer than the live and