o If when the oven is first switched on, it does not function
correctly, you should recheck that the terminal screws are
all fully tightened between the links. This should be done
before contacting the Baumatic Service Department.
o IMPORTANT: The appliance must NOT be connected to the
mains supply by means of a 13A plug and socket.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the oven is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.

Replacing the mains supply cable

If the mains supply cable is damaged, then it must be replaced with a
suitable replacement.
The mains supply cable should be replaced in accordance with the
following instructions:
o Switch the appliance off at the control switch.
o Open the terminal block on the back of the oven.
o Unscrew the terminal screws fixing the cable.
o Replace the cable with one of the same length and in accordance
with the specification given on page 25.
o The "green-yellow" earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
o The "blue" neutral wire must be connected to the terminal
marked with letter (N) - the live wire must be connected to the
terminal marked with letter (L).