Introducing the SGI 1400 Family of Servers
4
Warning:
The push-button on/off power switch on the front panel of the server
does not turn off the AC power. To completely remove AC power from the server, you
must unplug the AC power cord from each power supply or wall outlet.
The server operates reliably within most normal office or lab environmental limits. Select
a site that meets the following criteria:
Sited near a properly earthed, grounded, three-pronged power outlet
In the United States and Canada: a NEMA 5-15R outlet for 100-120 V, or a
NEMA 6-15R outlet for 200-240 V units
In other geographic areas: a properly earthed, grounded outlet in accordance
with the local electrical authorities and electrical code of the region
Clean and relatively free of excess dust
Well ventilated and away from sources of heat, with the ventilating openings on the
server kept free of obstructions
Away from sources of vibration or physical shock
Isolated from strong electromagnetic fields and noise caused by electrical devices
such as elevators, copy machines, air conditioners, large fans, large electric motors,
radio and TV transmitters, and high-frequency security devices
Access space provided so the server power cords can be unplugged from the power
supply or the wall outlet; this is the only way to remove AC power from the server
Clearance provided for cooling and airflow. For clearance requirements based on
chassis configuration, see Table 1 on page 2