Troubleshooting the CSS Hardware Components

Troubleshooting the CSS Fans

Troubleshooting the CSS 11501 Chassis Fans

Note
Cisco 11500 Series Content Services Switch Hardware Installation Guide
2-50
The following sections discuss:
Troubleshooting the CSS 11501 Chassis Fans
Troubleshooting the CSS 11503 Chassis Fans
Troubleshooting the CSS 11506 Fan Module
The CSS 11501 has six fans. When the CSS starts up and the fans are operational,
the following message appears:
CHMGR: All fans are present (6).
This message is displayed only if the logging level is set to the Info-6 or Debug-7
level.
If a fan fails when the CSS 11501 starts up, or fails during its normal operation,
the following message appears:
CHMGR: Missing fans. Expected 6. Found number.
The number variable indicates the total number of functioning fans. If the
CSS 11501 starts to overheat, the following message appears:
Temperature has reached x celsius for slot number
The x variable indicates the temperature of the CSS 11501.
When a fan failure occurs, obtain technical assistance.
Chapter 2
Cabling and Troubleshooting the CSS
78-17231-01