Troubleshooting The Css Power Supply; Troubleshooting The Css 11501 Power Supply; Troubleshooting The Css 11503 Power Supply; Troubleshooting The Css 11506 Power Supply - Cisco 11500 Series Hardware Installation Manual

Content services switch
Table of Contents

Advertisement

Chapter 2
Cabling and Troubleshooting the CSS

Troubleshooting the CSS Power Supply

Troubleshooting the CSS 11501 Power Supply

Note
78-17231-01
The following sections discuss:
Troubleshooting the CSS 11501 Power Supply

Troubleshooting the CSS 11503 Power Supply

Troubleshooting the CSS 11506 Power Supply

The CSS 11501 has one power supply as part of its chassis. When you power on
the CSS, the indications of a successful power up are that it boots properly and
become operational, and displays the following log message:
CHMGR: All power supplies are present (1).
This message is displayed only if the logging level is set to the Info-6 or Debug-7
level.
If you power on the CSS and it does not boot as indicated by the Status LEDs,
either:
There is no power to the power supply. Ensure that the CSS 11501 has power.
Check the power switch, power cord, and power source.
The power supply failed, obtain technical assistance.
Cisco 11500 Series Content Services Switch Hardware Installation Guide
Troubleshooting the CSS Hardware Components
2-45

Advertisement

Table of Contents
loading

Table of Contents