10. To connect the electrical power supply and connection cable for E90, E91 and E92 cars
A14
A13
X490
L
2
1
B1
B2
© BMW AG, Munich
A11
A12
090 1036 Z
A14
A13
H
X11003
090 1035 Z
B
3
090 1095 Z
1
090 1038 Z
01 29 0 420 167
Route branches A11-A14 to the passenger footwell.
Screw branch A12, brown cable, to earth post
connection X490.
For cars with M-ASK only
Cut cable loop A11, insulate and tie back to retrofit cable.
Cars with CCC only
Tie back cable loop A11 to retrofit cable.
All cars
If PIN 3 on plug X11003 is already occupied, cut the
socket contact off branch A13 and connect branch
A13 with miniature connector H to the red/white cable
from plug X11003 (PIN 3).
Connect branch A13, red cable, to plug X11003, blue
15-pin socket casing, PIN 3.
Tie back fuse holder A14 to retrofit cable.
If a fusible element of less than 7.5 A is present in slot 13,
fusible element L must be used.
For cars with M-ASK only
Disconnect the existing signal cable (1) from the
M-ASK (3).
Route the plug (2) on the existing signal cable (1) to the
installation site of the ACM unit.
Connect branch B1 (violet 10-pin plug) on connection
cable B to the installation site of the ACM unit.
Connect branch B2 (white 10-pin plug) to the M-ASK (1).
8/2006
(Z/Z)
17