Download Print this page
Jøtul ALLAGASH GF 3 BV Installation And Operation Instruction Manual
Jøtul ALLAGASH GF 3 BV Installation And Operation Instruction Manual

Jøtul ALLAGASH GF 3 BV Installation And Operation Instruction Manual

B-vent gas heater

Advertisement

Quick Links

GF 3 BV
ALLAGASH
B-Vent Gas Heater
f i r e - p a r t s . c o m
Installation
and Operation
Instructions
Warnock Hersey
C
All manuals and user guides at all-guides.com
IF THE INFORMATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL
• DO NOT USE THE PHONE IN YOUR
• FOLLOW YOUR GAS SUPPLIER’S
• IF YOU CANNOT REACH YOUR GAS
ASSUREZ-VOUS DE BIEN SUIVRE LES
INSTRUCTIONS DANS CETTE NOTICE POUR
REDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR EVITER TOUT DOMMAGE MATERIEL,
TOUTE BLESSURE OU MORTALIT’E.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.
• NE PAS TENTER D’ALLUMER L’APPAREIL
• NE TOUCHEZ A AUCUM NTERRUPTEUR.
• NE PAS VOUS SERVIR DES TELEPHONES SE
VOUS TROUVEZ.
• APPELEZ IMMEDIATEMENT VOTRE
FOURNISSEUR DE GAZ CHEZ UN VOISIN. SUIVEZ
US
LES INSTRUCTIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE
FOURNISSEUR DE GAZ, APPELEZ LE SERVICE
DES INCENDIES.
WARNING:
FOR YOUR SAFETY:
INSTALLATION:
SWITCHES.
BUILDING. IMMEDIATELY CALL YOUR GAS
SUPPLIER FROM A NEIGHBOR’S PHONE.
INSTRUCTIONS.
SUPPLIER, CALL THE FIRE DEPARTMENT.
AVERTISSEMENT:
NE PAS ENTREPOSER NI UTILISER D’ESSENCE
NI OU LIQUIDES INFLAMMABLES DANS LE
VOISINAGE DE CET APPAREIL OU DE TOUT
AUTRE APPAREIL.
L’INSTALLATION LE SERVICE DOIVENT ETRE
EXECUTES PAR UN INSTALLATEUR
QUALIFIE, AGENCE DE SERVICE OU LE
FOURNISSEUR DE GAZ.
TROUVANT DANS LE BATIMENT OU VOUS

Advertisement

loading
Need help?

Need help?

Do you have a question about the ALLAGASH GF 3 BV and is the answer not in the manual?

Questions and answers

Summary of Contents for Jøtul ALLAGASH GF 3 BV

  • Page 1 All manuals and user guides at all-guides.com WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY: DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
  • Page 2 All manuals and user guides at all-guides.com Model: Allagash B-Vent Gas Stove NATURAL GAS STOVE ONLY f i r e - p a r t s . c o m SUGGESTED TOOL LIST FOR INSTALLLATION AND SERVICE: *External regulator (for LPG only) *Piping which complies with local code *Manual shutoff valve *Sediment trap...
  • Page 3 All manuals and user guides at all-guides.com 28” 22 3/4” f i r e - p a r t s . c o m HEIGHT OF TOP EXIT IS CENTER 27 1/2” OF REAR EXIT IS 23” 13 1/4” 4” 18 1/2”...
  • Page 4 All manuals and user guides at all-guides.com f i r e - p a r t s . c o m...
  • Page 5 All manuals and user guides at all-guides.com f i r e - p a r t s . c o m...
  • Page 6 All manuals and user guides at all-guides.com ã 22 3/4” wide X 18 3/4” deep f i r e - p a r t s . c o m (measured from draft hood) (measured from top of stove) (measured from rear corners) MANTEL OR (for access to the lighting instructions) TRIM DEPTH...
  • Page 7 All manuals and user guides at all-guides.com VENTING REQUIREMENTS: UNUSED f i r e - p a r t s . c o m • •...
  • Page 8 All manuals and user guides at all-guides.com Type B vent or Listed Flexible Gas Liner. f i r e - p a r t s . c o m max. height 35’ min. height 7’ Always maintain the proper clearance to mantel and trim WARNING FAILURE TO POSITION THE PARTS IN...
  • Page 9 All manuals and user guides at all-guides.com VENTING CONFIGURATIONS FOR THE ALLAGASH B-VENT Maximum 45° or 90° 35 feet elbow Minimum 4 feet. Minimum 7 feet 45° or 90° 7 feet elbow f i r e - p a r t s . c o m required 45°...
  • Page 10 All manuals and user guides at all-guides.com f i r e - p a r t s . c o m...
  • Page 11 All manuals and user guides at all-guides.com See Figure 2. 1/4” 1/4” BE SURE TO REMOVE WHEN RE-INSTALLING THE BURNER TUBE BE SURE THE BLACK RUBBER THAT THE TUBE IS PULLED FORWARD IN THE GASKET FROM THE MOUNTING HOLES, SECURE WITH THE TWO 1/4” VALVE!!! SCREWS.
  • Page 12 All manuals and user guides at all-guides.com PART · · · · f i r e - p a r t s . c o m Pressure test point as located on the front of the valve.
  • Page 13 All manuals and user guides at all-guides.com HIGH ALTITUDE INSTALLATIONS: f i r e - p a r t s . c o m...
  • Page 14 All manuals and user guides at all-guides.com AIR SHUTTER ADJUSTMENT/FLAME APPEARANCE: Ø t i k t i k f i r e - p a r t s . c o m 1/4” 1/4” ATTENTION: Air shutter should never be LESS than 1/8”...
  • Page 15 All manuals and user guides at all-guides.com WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN. f i r e - p a r t s . c o m...
  • Page 16 All manuals and user guides at all-guides.com INSTALLING THE OPTIONAL BLOWER: BUT DO NOT REMOVE f i r e - p a r t s . c o m 7G68FCDÃ XCDU@PAAÃ S@9G P XÃ Direction under the stove.
  • Page 17 All manuals and user guides at all-guides.com INSTALLING THE OPTIONAL WALL THERMOSTAT OR REMOTE: SPILL SWITCH f i r e - p a r t s . c o m Source: HEARTH- Gas Training Manual CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS.
  • Page 18 All manuals and user guides at all-guides.com CHECKING THE SYSTEM: CAUTION: DO NOT ATTEMPT TO ALTER THE FLAME APPEARANCE BY POSITIONING THE GAS VALVE IN ANY OTHER POSITION OTHER THAN THE FULL “ON” POSITION. f i r e - p a r t s . c o m 1”...
  • Page 19 All manuals and user guides at all-guides.com OPERATION OF APPLIANCE: MAINTENANCE: f i r e - p a r t s . c o m CAUTION: DO NOT OPERATE THIS APPLIANCE WITH GLASS REMOVED CRACKED OR BROKEN. REPLACEMENT GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
  • Page 20 All manuals and user guides at all-guides.com SERVICE LOG: First Year SERVICE LOG: Two Year f i r e - p a r t s . c o m MODEL NAME: Allagash B-Vent Stove SERIAL NUMBER:__________________________ DATE OF PURCHASE:_______________________ AUTHORIZED DEALER:_____________________ NAME OF INSTALLER:______________________ TYPE OF FUEL:_____________________________ WAS STOVE CONVERTED?___________________...
  • Page 21 All manuals and user guides at all-guides.com ALLAGASH B-VENT PARTS LIST Cast Iron Parts / Enamel Colors PART MATTE BLU/BLK IVORY GREEN INDIGO -On/Off Switch f i r e - p a r t s . c o m Hardware Accessories Conversion Kit to NG 154375...
  • Page 22 All manuals and user guides at all-guides.com GF3 BV Allagash Illustrated Parts Breakdown f i r e - p a r t s . c o m...
  • Page 23 All manuals and user guides at all-guides.com LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. B. BEFORE LIGHTING, WHAT TO DO IF YOU SMELL GAS: f i r e - p a r t s .
  • Page 24 All manuals and user guides at all-guides.com f i r e - p a r t s . c o m Stoves and fireplaces must be installed to conform to local and national building regulations. Before preparing for the installation of the appliance, it is important that the instructions issued with the unit are carefully read an strictly adhered to.