INSTALLING THE OUTSIDE TERMINAL

Figures 14 and 15 show the installation of the outside terminal. Follow the instruction below the
figures to successfully complete this task.
FIGURE 14
-
Determine the terminal location.
-
Cut an 8 1/4 in diameter hole through the wall. This is slightly larger than the O.D. of the
terminal. Prior to cutting make sure you have the proper ground clearances.
-
Separate the inner and outer terminal sections.
-
Slide the outer wall plate over the outer section of the terminal until it until it rests against the
bead.
-
From outside the building insert the outer section of the terminal through the hole until it rests
against the outer wall.
-
From inside the building slide the inner wall plate over the outer terminal section and secure
using (4) screws.
-
Position the outer section so that the seam on the flue collar is on top of the air intake on the
bottom. Secure the outer section by tightening the gear clamp around it. The gear clamp is
factory welded to the inner wall plate.
-
Seal around the bead and edge of the outer wall plate with a weather proof sealant to prevent
water infiltration.