3.3 Installing the boiler.

The appliance must be installed
exclusively on a vertical solid wall capable
of supporting its weight.
■ The boiler should be fitted within the
building unless otherwise protected by a
suitable enclosure i.e. garage or
outhouse. (The boiler may be fitted
inside a cupboard)
■ If the boiler is sited in an unheated
enclosure then it is recommended to
leave the ON/OFF switch always in ON
position to give frost protection.
■ If the boiler is installed in a room
containing a bath or shower reference
must be made to the relevant
requirements.
■ Appliance is approved for installation on
combustible walls.
In order to allow access to the interior of
the boiler for maintenance purposes, it is
important that the minimum distances
indicated in figure 1 are respected. To
make the installation easier, the boiler is
supplied with a template to enable the pipe
connections to be positioned prior to fixing
the appliance to the wall.
To install the appliance, proceed as follows
(see fig. 2):
a. Use a level (of not less than 24" long)
to mark a horizontal line on the wall
where the appliance is to be fitted.
b. Position the top of the template along
the line drawn with the level,
respecting the distances indicated.
Then mark the centres of the positions
of the two wall screws or anchors.
Finally, mark the positions of the water
and gas pipes.
c. Remove the template and install the
domestic hot and cold water pipes, the
gas supply pipe and the central heating
pipes using the fittings supplied with
the unit.
Fix the boiler to the wall using the bracket
and connect the pipes.
INSTALLATION INSTRUCTIONS
Fig. 2
L
X
MINIMUM DISTANCES [INCHES]
Model
X
Y
L
16
PCC 34
2.5
2.5
Y
H
A
B
40
14
12
Fig. 1
18

Hide quick links: