3.3 Installing the boiler.

The appliance must be installed
exclusively on a vertical solid wall capable of
supporting its weight.
■ The boiler should be fitted within the building
unless otherwise protected by a suitable
enclosure i.e. garage or outhouse. (The boiler
may be fitted inside a cupboard)
■ If the boiler is sited in an unheated enclosure
then it is recommended to leave the ON/OFF
switch always in ON position to give frost
protection.
■ If the boiler is installed in a room containing a
bath or shower reference must be made to the
relevant requirements.
■ Appliance is approved for installation on
combustible walls.
In order to allow access to the interior of the
boiler for maintenance purposes, it is important
that the minimum distances indicated in figure 1
are respected. To make the installation easier,
the boiler is supplied with a template to enable
the pipe connections to be positioned prior to
fixing the appliance to the wall.
To install the boiler, proceed as follows (see fig.
2):
a. Use a level (of not less than 24" long) to mark
a horizontal line on the wall where the boiler
is to be fitted.
b. Position the top of the template along the line
drawn with the level, respecting the distances
indicated. Then mark the centres of the
positions of the two wall screws or anchors.
Finally, mark the positions of the water and
gas pipes.
c. Remove the template and install the domestic
hot and cold water pipes, the gas supply pipe
and the central heating pipes using the
fittings supplied with the boiler.
Fix the boiler to the wall using the bracket and
connect the pipes.
INSTALLATION INSTRUCTIONS
Fig. 2
Fig. 2
L
X
Y
MINIMUM DISTANCES [INCHES]
Model
X
Y
L
H
17.7
RKA 25
2.5
2.5
40
A
B
8