B - 6
D i a g n o s t i c s
Erro r Code
OSD
BATTERY
E 09
E 10
SERIALNO
E 11
INVALID UNIT
ADDRESS
E 12
POST ERROR
E 13
BOOT
STARTUP
E 14
E 15
TSI INVALID
FLASH BAD
E 16
NUMBER
E 17
BAD PLATVAL
*E 00 and E 01 cannot be displayed while the DCT2000 is off. The other errors will display on
the LED display when the DCT2000 is off.
There are five different tuners that could appear on the OSD display:
V1000D2
V1000D3C
V860
V860D
V860DL
D C T 2 0 0 0 I n s t a l l a t i o n M a n u a l
Cause
Dead battery or memory has not been
initialized; occurs if battery fails to
keep the RAM alive during
power-down; causes DCT2000 to be
disconnected
Invalid serial number
Invalid unit address
POST failed
Sys_boot initialization failure
DCT2000 system startup failure
TSI structure is corrupted
Bad flash number specified for Initiate
Flash Platform
Bad platform validation step number
Remedy
Return DCT2000 for repair;
requires factory
initialization message
Not used at this time
Return DCT2000 for repair;
requires a unit creation
message
Not used at this time
Power cycle box; if
repetitive, return for repair
Power cycle box; if
repetitive, return for repair
Power cycle box; if
repetitive, return for repair
Error logged, ignore
Error logged, ignore