Power supplies

The server supports up to three 1100-watt, hot-swap power supplies that support N+N or N+1 redundancy
depending on the configuration:
If only two or three processors are installed or four processors less than 140 W are installed, then one
power supply is required and the second supply can be redundant if installed (N+N where N=1)
If four 140W processors are installed, then two power supplies are required for a fully-populated
server with no redundancy (or three power supplies can be installed with the third redundant N+1,
where N=2)
If four 140W processors are installed, only one power supply can be installed with no redundancy (or
two power supplies can be installed with the second redundant, N+1 where N=1) provided these limits
are met:
Maximum 16 DIMMs
Maxumum 4 disk drives
The server comes standard with one or two power supplies, depending on the model. The following table
lists the power supplies.
Table 13. Power supplies
Part number
Feature
code
49Y7342
2593
Each power supply ships standard with one 2.8 m, 10A/100-250 V, C13 to IEC 320-C14 Rack Power
Cable.
IBM System x3755 M3
Description
1100W Redundant Power Supply
Maximum
Standard models
supported
where used
3
All