REMOVAL
+
WARNING: When disconnecting battery cables,
always remove the black negative cable first then
the positive cable (red!. Care should be taken while
disconnecting above mentioned cables otherwise bat-
tery
post breakage could occur.
CLEANING
"Clean the battery casing,
vent
caps,
cables and
battery
posts using a solution of baking soda and water.
_
CAUTION: Do not allow cleaning solution to enter
. " battery interior since
it
will destroy the electrolyte.
Remove corrosion from battery cable
terminals
and
bat-
tery posts using a firm copper brush.
INSPECTION
Visually inspect battery casing for cracks or other possi-
ble damage.
If
casting is damaged, replace battery.
Inspect battery posts for security of mounting. Inspect
for cracked or damaged battery caps. Ensure that vent
holes are unobstructed. Replace defective caps.
If
vent
hole
is blocked, clean using a firm strand of wire
.
+
WARNING: Some battery caps do not have holes.
Make sure that overflow tube is unobstructed.
HYDROMETER TEST
Do
not suck
in
too much
electrolyte
Float
must be
free
Take
reading
at
eye
level
SECTION 04 ELECTRICAL
SUB-SECTION 04
(BATTERY)
BATTERY
A hydrometer measures a battery's
state of charge in
terms of specific gravity. Most hydrometers
only
read
true at 2]0 C (SO° F)
In order to obtain correct readings, adjust the initial
reading by adding
.004
points to the hydrometer readings
for each 5.5°C (10°F) above 27°C (SO°F) and by
sub-
tracting
.004 points for every 5.5°C (10°F) below 2]oC
(SO°F).
THE ILLUSTRATION WILL AID YOU IN FINDING THE
CORRECT READING
.
°
C
o
f
At
3S
100
add
32
90
"
27
80
21
70
subtract
16
60
10
50
4
40
-1
30
-7
20
-12
10
-18
0
-23
-10
-29
-20
-34
-30
-40
-40
EXAMPLE NO
.
1
Temperature below 27
0
C
(80
0
F)
Hydrometer Reading 1
250
ACid
temperature
_7
°
C
(20
°
F)
Subtract .024 Sp
.
Gr
Corrected Sp Gr.
IS
1
226
"
"
"
"
"
"
"
"
"
"
"
OOS
to the reading
.004
1/
"
"
correct reading
.004
from the
reading
.008
I I
"
"
.012
I I
I I
I I
016
I I
I I
I I
020
/I
"
I I
024
I I
"
I I
028
"
1/
1/
.032
1/
I I
"
036
" " "
040
I I
I I
I I
.044
"
I I
"
.048
"
I I
I
J
EXAMPLE NO
2
Temperature above
27
°
C (BO
°
F)
Hydrometer Reading 1
.235
ACid temperature
38
°
C
(100
°
F)
Add
.
008
Sp.
Gr
Corrected Sp Gr
IS
1
243
_
CAUTION: Do not install a partially charged bat-
. " tery on a snowmobile since the casing may crack
at freezing temperature. The following chart shows the
freezing point of the electrolyte in relation to the bat-
tery's state of charge.