Step 4 The Gas Supply Line - Heat-N-Glo BAY-INS Installer's Manual

Vented gas fireplace heater
Table of Contents

Advertisement

Step 4
The Gas
Supply Line
The gas line should be
installed by a qualified
service technician.
11
NOTE: Have the gas supply line installed by a
qualified service technician in accordance with all
building codes.
NOTE: Before the first firing of the fireplace, the gas
supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly
size the gas supply line leading to the 1/2 inch
(13 mm) hook-up at the unit.
This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line.
To install the gas supply line:
• A listed 1/2 inch (13 mm) manual shut-off valve and
a listed flexible gas connector are connected to the
1/2 inch (13 mm) inlet of the control valve.
• A 1/8 inch (3 mm) N.P.T. plugged tapping, acces-
sible for test gauge connection, should be provided
for in the gas supply line leading to the unit's shut-
off valve.
• Locate the gas line access hole in the outer casing
of the insert.
• Open the lower grille, insert the gas supply line
through the gas line hole, and connect it to the shut-
off valve.
• When attaching the pipe, support the control so that
the lines are not bent or torn.
• After the gas line installation is complete, use a
soap solution to carefully check all gas connections
for leaks.
WARNING
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
Figure 7. Gas Supply Line
USE A WRENCH ON
USE A WRENCH ON
SHUT-OFF VALVE WHEN
SHUT-OFF VALVE WHEN
TIGHTENING GAS LINE.
TIGHTENING GAS LINE.
MANUAL SHUT-OFF
MANUAL SHUT-OFF
VALVE
VALVE
GAS VALVE
FLEX CONNECTOR