Maintenance Procedures
Lamp Replacement - Incandescent
Parts:
71.2529.0120
71.2526.0230
71.9685.0082
Tools:
•
Cotton gloves or finger cots.
WARNING:
To remove and replace incandescent lamp:
Step 1. Remove power from luminaire.
WARNING:
replacing.
Step 2. Set the luminaire head horizontally.
Step 3. Engage service tilt lock to secure luminaire head in horizontal position to access
Step 4. As shown in
02. 96 85. 001 0 A
1EA
1200 WATT TUNGSTEN HALOGEN LAMP, 120 VAC
(VL500 AND VL500D MODELS)
1 EA
1000 WATT TUNGSTEN HALOGEN LAMP, 230 VAC
(VL500 AND VL500D MODELS)
1 EA
1200 WATT TUNGSTEN HALOGEN LAMP, 80 VAC
(VL500 80V MODELS)
Remove power from luminaire before performing maintenance.
Lamps will be extremely HOT after operation. Allow lamp to cool before
heatsink latch.
Figure 3
, at heatsink assembly, open latch and swing open back of
luminaire.
CAUTION:
Ensure lamp is seated
straight in socket before
re-installing backcap.
Figure 3: Lamp Replacement - Incandescent
21-May-2009
Heatsink
Assembly
Latch
Incandescent Lamp
2
M
:
AINTENANCE
25