CAPACITOR CHECK

9. Check or replace start capacitor, disconnect bleed resistor before checking for shorted capacitor.
10. Check or replace run capacitor (if supplied) check for shorted capacitor or either terminal grounded to case.

FIGURE 22. GEAR MOTOR OVERLOAD

SAFETY CONTROLS

Your icemaker unit has several safety and control devices incorporated into its design.
WARNING: None of the below described devices should ever be "bypassed" to allow the
unit to function.
The safety and control system shut-off devices are:
1. Low water shut off reed switch located in icemaker float assembly. (Automatic reset type.)
See Figure 5
2. Gearmotor thermal overload, manual reset type (red button on motor). See Figure 22
3. Compressor thermal overload, automatic reset type. See Figure 20
4. Anti-freeze relay and associated circuit. See wiring diagrams, pages 10 and 11.
5. Main service switch located on top of the control box. See Figure 15
6. Bin Control. See Figure 15
7. High pressure cut out (water cooled only).
GEAR MOTOR OVERLAY