24" min.
(610 mm)
For ceiling exit using close clearance listed chimney
1. Suspend a plumb bob from ceiling above unit so that weight is hanging in center of flue
exit. (A small weight on a string will serve as a plumb bob). Mark ceiling where string is
suspended to locate center of chimney hole.
2. After locating center of hole install ceiling support box, chimney, flashing and rain cap
using listed 2100° UL 103 HT chimney only. Only use pipe listed in this manual.
REFER TO CHIMNEY MANUFACTURER'S INSTRUCTIONS FOR ASSEMBLY
AND DISASSEMBLY OF CHIMNEY PARTS. BE SURE TO FOLLOW CHIMNEY
INSTRUCTIONS FOR PROPER CLEARANCES TO COMBUSTIBLE AND PROPER
AIR SPACING REQUIRED.
3. Add additional pipe until both of the following are met:
(a) Chimney pipe is 3 feet higher than roof at point where it penetrates roof and
(b) Chimney pipe height is at least 2 feet higher than any part of roof within 10 feet of
chimney. See (Page 27, Figure 12D).
RAIN CAP
36" TYP.
FLASHING
RADIATION SHIELD
20 FT. MAX.
OUTSIDE AIR DUCT THROUGH FLOOR WHEN
MOBLE HOME IS NOT UNDERPENNED
Figure 12D
CAUTION
Page 27
24" min.
(610 mm)
OUTSIDE AIR DUCT THROUGH UNDERPENNED
RAIN CAP
36" TYP.
FLASHING
RADIATION SHIELD