SMA Solar Technology AG
Test voltage (DC)
Test surge voltage
Surge testing voltage with serial interface
Internal consumption in night mode

Mechanical data

Width x height x depth
Weight

Climatic Conditions

Extended temperature range *
Extended humidity range *
Extended air pressure range *
Temperature range **
Operation temperature range
Maximum operating altitude above mean sea
level
* according to DIN EN 50178:1998-04, installation type C, class 4K4H
** according to DIN EN 50178:1998-04, transport type E, class 2K3
Features
Topology
Cooling concept
Fan connection

General data

Protection rating in accordance with
DIN EN 60529
Protection class
Noise emission (typical)
Installation Guide
468 mm x 613 mm x 242 mm
31 kg
− 25 °C ... +60 °C
0 % ... 100 %
79.5 kPa ... 106 kPa
− 25 °C ... +70 °C
− 25 °C ... +60 °C
3,000 m
Transformerless
OptiCool
Designed for safe disconnection
In accordance with DIN EN 50178:1998-04
IP65
≤ 31 dB(A)
SMC6-8TL-IEN101040
Technical Data
2.15 kV
4 kV
6 kV
0.25 W
I
75