Extreme Networks E4G Series Hardware Installation Manual page 115

Hide thumbs Also See for E4G Series:
Table of Contents

Advertisement

Table 13: E4G-200-12x Cell Site Router Technical Specifications (Continued)
Input current
Heat dissipation
Power consumption
E4G-200-12x router with T1/E1 module
Input current
Heat dissipation
Power consumption
E4G-200-12x router with clock module and T1/E1 module
Input current
Heat dissipation
Power consumption
Safety Standards
North American Safety
European Safety
International Safety
EMI/EMC Standards
North America EMC
European EMC
International EMC
Directives
E4G Series Routers Hardware Installation Guide
1.61 A @ +24V
0.82 A @ –48 V
40 W, 137 BTU/hr
40 W, 137 BTU/hr
1.81 A @ +24 V
0.93 A @ –48 V
44.5 W, 152 BTU/hr
44.5 W, 152 BTU/hr
2.02 A @ +24 V
1.03 A @ –48 V
49.5 W, 169 BTU/hr
49.5 W, 169 BTU/hr
UL 60950-1:2007 2nd Ed., Listed Device (US)
CSA 22.2 #60950-1-03 2nd Ed. 2006-07 (Canada)
Complies with FCC 21 CFR Chapter 1, Subpart J (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
CB Scheme IEC 60950-1: 2005 2nd Ed.+National Differences
IEC/EN 60825-1:2007 (Lasers Safety)
IEC/EN 60825-2:2004+A2:2010 (Optic Fiber Systems)
GS-TUV Mark EN 60950-1:2006 2nd Ed.
AS/NZS 60950-1 (Australia /New Zealand)
FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
EN 55022:2010 Class A
EN 55024:2010 Class A includes EN 61000-4-2, 3, 4, 5, 6, 11
EN 55011:2009+A1:2010
EN 61000-3-2,8-2006+A2:2009 (Harmonics)
EN 61000-3-3 2008 (Flicker)
EN 61000-6-4:2007 (Emissions for Industrial, Scientific & Medical)
EN 61000-6-2:2005 (Immunity for Industrial, Scientific & Medical)
CISPR 22: 2010 Ed 5.2, Class A (International Emissions)
CISPR 24:2010 Class A (International Immunity)
IEC 61000-4-2:2008/EN 61000-4-2:2009
Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A
IEC 61000-4-3:2008/EN 61000-4-3:2006+A1:2008
Radiated Immunity 10V/m, Criteria A
IEC 61000-4-4:2004 am1 ed.2./EN 61000-4-4:2004/A1:2010
Transient Burst, 1 kV, Criteria A
IEC 61000-4-5:2005 /EN 61000-4-5:2006
Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC 61000-4-6:2008/EN 61000-4-6:2009
Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A
IEC-61000-4-11:2004
Power Dips & Interruptions, >30%, 25 periods, Criteria C
E4G-200-12x Cell Site Router