Figure 14. Performance Data Definitions; Figure 15. Performance Data Definitions (Continued) - ADTRAN 3192 HDSL4 Installation And Maintenance Practice

Remote, span powered transceiver
Table of Contents

Advertisement

Control Port Operation
Circuit ID:
H4TUC, H4TUR, and H4R LOOP Related:
ES-L
SES-L
UAS-L
DS1 and DSX-1 Line Related:
ES-L
SES-L
LOSS-L
PDVS-L
B8ZS-L
CV-L
NOTE: Reverse video indicates invalid data due to a terminal restart (or power
cycle), a data register reset, or a system date or time change.
N.
Next
P.
Previous
Circuit ID:
DS1 and DSX-1 Path Related:
ES-P
SES-P
UAS-P
SAS-P
ES-PFE
CV-P
NOTE: Under a UAS-P condition, ES-P and SES-P counts are inhibited.
Under a SES-L or SES-P condition, the respective CV-L or CV-P count is
inhibited.
P.
Previous
16
Performance Data Definitions
Errored Seconds
Severely Errored Seconds
Unavailable Seconds
Errored Seconds
Severely Errored Seconds
Loss of Signal Seconds
Pulse Density Violation Secs
B8ZS Seconds
Code Violation Count
Selection:

Figure 14. Performance Data Definitions

Performance Data Definitions
Errored Seconds
Severely Errored Seconds
Unavailable Seconds
SEF/AIS Seconds
Far End Errored Seconds
Code Violation Count
Selection:

Figure 15. Performance Data Definitions (Continued)

3192 H4TU-R, Span Powered Installation and Maintenance Practice
HDSL4 Framing
CRC>=1 or LOSW>=1
CRC>=50 or LOSW>=1
>10 cont. SES-Ls
Superframe and Extended Superframe
(BPV+EXZ)>=1 or LOS>= 1
(BPV+EXZ)>=1544 or LOS>=1
LOS>= 1
EXZ>=1; >7 zeros if B8ZS, >15 if AMI
B8ZS coded signal received
(BPV+EXZ) count
Superframe
FE>=1 or
SEF>=1 or AIS>=1
FE>=8 or
SEF>=1 or AIS>=1
>10 cont. SES-Ps
SEF>=1 or AIS>=1
n/a
FE count
06/01/04 09:29:45
06/01/04 09:29:45
Extended Superframe
CRC>=1 or
SEF>=1 or AIS>=1
CRC>=320 or
SEF>=1 or AIS>=1
>10 cont. SES-Ps
SEF>=1 or AIS>=1
PRM bits G1-G6,SE,
or SL=1, or RAI
CRC error count
61223426L12-5A

Advertisement

Table of Contents
loading

Table of Contents