Current System Status Screen; Figure 9. Current System Status Screen; Table 13. Hdsl, Ds1, And Dsx-1 Key Definitions - ADTRAN HDSL DDM+ HTU-C Installation And Maintenance Practice

Transceiver unit for central office
Table of Contents

Advertisement

HDSL DDM+ Transceiver Unit for Central Office Installation and Maintenance Practice

Current System Status Screen

The Current System Status screen, illustrated in
information for both the DDM+ HTU-C and the HTU-R.
Circuit ID:HNTSVLALHDSL
LOOP #1 <NETWORK> LOOP #2
----------HTU-C----------
29(29) dB
YES
000/00000
000/00000
000/00000
LOOPBACKS INACTIVE
HTU-C Margin (dB)
LP1
LP2
Press "Z" to zero registers, "X" to restart MIN/MAX, "M" for Main Menu,
Type the letter "
" at the Current System Status screen or the Performance History screen in
Z
order to reset the current performance registers to zero on both the Current System Status
and Performance History screens. A prompt requires user confirmation to execute the zero
registers function.
Figures 9
and
10
consolidate current information for the HDSL, DSX-1, and DS1 interfaces. A
key to the information provided is found in the center of the screen and defined in
below. Arrows indicate the key applies to both the DDM+ HTU-C and HTU-R.

Table 13. HDSL, DS1, and DSX-1 Key Definitions

Indicator
LOSS
SYNC
ES 15M/24H
SES 15M/24H
UAS 15M/24H
1. LOSS is typically several dB less than the insertion loss measured at 200 kHz. The LOSS measurement is a
better indication of the loop's attenuation of the 2B1Q signal than the insertion loss measured at a single
frequency. ADTRAN HDSL can operate on cables with an excess of 30 dB LOSS.
2. The first number is for the current 15-minute period and the second is the current 24-hour period (Loop 1
and Loop 2 numbers are displayed).
22
CURRENT SYSTEM STATUS
29(29) dB
<-
LOSS (CUR MAX)
YES
<-
SYNC
000/00000
<-
ES
000/00000
<-
SES
000/00000
<-
UAS
DSX-1
---------------------------
CUR/MIN/MAX
ESF
<-
B8ZS
<-
20/20/20
0-133 <-
20/20/20
N/A
<-
00000 <-
00000 <-
00000 <-
00000 <-
NONE
<- ALARMS
"H" for HDSL Range Extender #1 (HRE) View.

Figure 9. Current System Status Screen

Definition
Pulse attenuation measurement
HDSL loop 1 and loop 2 sync status
Errored seconds
Severely errored seconds
Unavailable seconds
Figure
9, provides quick access to status
LOOP #1 <CUSTOMER> LOOP #2
-----------HTU-R----------
->
29(29) dB
->
YES
15M/24H
->
000/00000
15M/24H
->
000/00000
15M/24H
->
000/00000
LOOPBACKS INACTIVE
DS1
HTU-R Margin (dB)
FRAME
->
ESF
CODE
->
B8ZS
LB0
->
0 dB
LP1
NIU
->
YES
LP2
BPV
->
00000
ES
->
00000
SES
->
00000
UAS
->
00000
->
NONE
(1)
(2)
(2)
(2)
MM/DD/YY hh:mm:ss
30(30) dB
YES
000/00000
000/00000
000/00000
CUR/MIN/MAX
20/20/20
20/20/20
Table 13