Figure 16 and Figure 17 display the Performance
Data Definitions Screens.
CIRCUIT ID:
H2TUC, H2TUR, and H2R LOOP Related:
ES-L
Errored Seconds
SES-L
Severely Errored Seconds
UAS-L
Unavailable Seconds
DS1 and DSX-1 Line Related:
ES-L
Errored Seconds
SES-L
Severely Errored Seconds
UAS-L
Unavailable Seconds
CV-L
Code Violation Count
NOTE: Reverse video indicates invalid data due to a terminal restart (or power
cycle), a data register reset, or a system date or time change.
N.
Next
P.
Previous

Figure 16. Performance Data Definitions Screen, Loop Related

CIRCUIT ID:
DS1 and DSX-1 Path Related:
ES-P
Errored Seconds
SES-P
Severely Errored Seconds
UAS-P
Unavailable Seconds
CV-P
Code Violation Count
NOTE: Under a
Under a SES-L or SES-P condition, the respective CV-L or CV-P count is
inhibited.
P.
Previous

Figure 17. Performance Data Definitions Screen, Path Related

61222004L2-5A
Performance Data Definitions
Selection:
Performance Data Definitions
UAS-P condition, ES-P and SES-P counts are inhibited.
Selection:
Section 61222004L2-5, Issue 1
HDSL2 Framing
CRC>=1 or LOSW>=1
CRC>=50 or LOSW>=1
>10 cont. SES-Ls
Superframe and Extended Superframe
(BPV+EXZ)>=1 or LOS>= 1
(BPV+EXZ)>=1544 or LOS>=1
>10 cont. SES-Ls
(BPV+EXZ) count
Superframe
Extended Superframe
FE>=1 or
SEF>=1 or AIS>=1
FE>=8 or
SEF>=1 or AIS>=1
>10 cont. SES-Ps
FE count
01/01/00 03:38:08
01/01/00 03:38:27
CRC>=1 or
SEF>=1 or AIS>=1
CRC>=320 or
SEF>=1 or AIS>=1
>10 cont. SES-Ps
CRC error count