INSTALLATION continued

WATER CONNECTION

These units come equipped with either a direct connect, rear mounted quick disconnect fluid control
valve, or a 2 cup water tank with tank drain and supply pump. It is vital that all water supply lines be
thoroughly flushed with clean water before being connected to the steamer.
The Star Fast-Steamer has a water injection system, to ensure your new equipment works at its premium,
we recommend that a water softener is used in areas where hard water is present. Contact your local
water equipment system provider to assist you in determining your specific water quality, or contact Star
Technical support for assistance, -800-807-9054.
Direct Connect Water Supply Installation
. Make certain the water valve that
will be suppling the unit is turned
off.
2.
Connect the 1/4" I.D. flexible
tubing to the outlet side of the water
source and secure with clamps
provided.
. Holding the end opposite end
over a bucket, turn the water valve on until there is a good consistent supply of water
(this removes any air from the system and flushes it of any particles that may be present).
4. Turn off the water valve.
5.
Push the check valve fitting into the water inlet located on the rear of the unit.
Make certain the connection is securely attached by lightly tugging on it.
6. Turn on water valve, Turn the knob on the regulator until the guage reads 26 psi.
Check for leaks.
Reservoir Water Units
1.
With unit in final position, open reservoir lid.
2. Check and make sure the reservoir is free of debris
and material that may interfere with its operation.
3.
The unit comes with a washer strainer which fits
over the water inlet (see illustration), verify this is
correctly in position. Periodically check strainer and
clean and replace as often as necessary.
4. Pour tap water into reservoir until the water level is
/4" from the top.
5. Closed lid.
6.
Check water level during daily operation and fill as needed.
Regulator
26 psi
To Steamer
6
Water
Source
Filter
IL1532
Guage
Lid
Strainer
Water Inlet
IL1537