Making A Cascade Connection - Tascam DM-3200 Release Notes

V 1.50
Hide thumbs Also See for DM-3200:
Table of Contents

Advertisement

Making a cascade connection

This section explains how to make a cascade connection
between two DM-3200s that are running Version 1.20.
1 Using the TASCAM cascade cable (PW-1000CS –
sold separately), connect the CASCADE ports of the
two DM-3200.
WARNING
Only use the special TASCAM cascade cable. Use of
any other type of cable may result in damage to the
equipment.
2 Set one of the DM-3200 units to be the cascade
master, and the other the cascade slave.
To set the master and slave, display the
using the
DIGITAL
key in the
ENTRY
section, and use the
POD 3
the
key) to display the
DIGITAL
the
of one of the units to
ID
MASTER
Figure 13: DIGITAL>CASCADE screen
NOTE
Set the unit ID while the ON/OFF set-up is OFF. You
cannot change the ID set-up while it is ON.
3 Turn the ON/OFF setting on the
sub-screen of the cascade master to
Move the cursor to the
ON/OFF
key. A confirmation screen will come up. Check
ENTER
the setting and press the
ENTER
NOTE
ON/OFF status cannot be changed while the timecode
is running.
4 When a cascade connection is established, a pop-up
message "
Cascade connection established
displayed. Press the
ENTER
NOTE
If a cascade connection was not properly established,
a pop-up message "Cascade Slave not found. Cascade
connection not established" will be displayed.
screen
DIGITAL
SCREEN MODE/NUMERIC
key (or continue pressing
sub-screen. Set
CASCADE
, and the other to
SLAVE
CASCADE
ON
.
button and press the
key again to confirm.