INSTALLATION INSTRUCTIONS - GAS PRODUCTS

Connect to the gas supply

Means of isolation shall be provided at the
shut off point by either an approved quick
connect device or a Type 1 manual shut
off valve. The outlet of the quick connect
device shall be at, or below, the horizontal
position.
Connection to the gas supply should be
made using the Aquaknect AS/NZS 1869
class B hose assembly with an internal
diameter of not less than 10mm and
regulator (regulator for use with natural
gas)
NOTE: Maximum length of hose 900mm.
The temperature rise of the areas at the
rear of the cooker that are likely to come
into contact with the flexible hose do not
exceed 70˙C.
The inlet to the cooker is ½" BSP internal
situated at the rear right corner. Fit the
bayonet connection. This should be
located so as to ensure that the flexible
connector hose does not kink.
Under no circumstances should the flexible
connector be allowed to come into contact with
the vertical oven flue tubes on the rear of the
appliance.
Use a 900mm - 1125mm length of
flexible connector.
Ensure that all pipework is of the correct
rating for both size and temperature.
Natural Gas - Flexible connections should
comply with BS 669. Parts of the appliance
likely to come into contact with a flexible
connector have a temperature rise of less
than 70°C.
After installation, make sure all connections
are gas sound.

Commissioning

Burner aeration
All burners have fixed aeration and no
adjustment is possible.
Pressure setting
Natural Gas @ 1.00kPa
Pressure test point
Use the oven injector.
Grill - Open the top oven / grill door.Push
in and turn the top oven / grill control
knob clockwise to the 'FULL ON' position.
Hold the control knob in, and press the
ignition switch (if fitted) or hold a lighted
match or taper to the burner. Hold the
control knob in for 15 seconds. Do not
hold the control knob in for longer that 15
seconds. If the burner fails to light within
this time, release the control knob and
wait one minute before attempting further
ignition. until the burner lights.
Hob burner - Turn the control knob to the
FULL ON position, wait a second before
pressing the ignition switch or holding a
lighted match or taper to the burner. Hold
the control knob in for 15 seconds. Do not
hold the control knob in for longer that 15
seconds. If the burner fails to light within
this time, release the control knob and
wait one minute before attempting further
ignition.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsg 60doFsg 60 dopFsg 60tcFsg 60tc lpg

Table of Contents