CONNECT TO THE ELECTRICITY AND GAS SUPPLY

WARNING: This appliance must be earthed.
This appliance must be fitted to a switch providing all pole disconnection with a minimum contact
separation of 3mm.
Access to the mains terminal is gained by removing the terminal block cover at the rear of the appli-
ance.
Connection should be made with a suitable flexible cable with a minimum temperature rating of
70°C.
First strip the wires then push the cable through the cable clamp.
Connect the cable to the terminal block and tighten the cable clamp screws - see diagram.
Refit the terminal box cover.
Sufficient cable should be used to allow the cooker to be pulled out, but must hang clear of the floor
so it does not become twisted or trapped when the cooker is pushed back.
The terminal block screws and clamps can be damaged by excessive tightening and untightening. DO
NOT USE POWER TOOLS!
Single Phase Connection (240V ac 50Hz)
2
1
L
Shorting
Shorting
Links
Link
Connect cable to terminal block:
L to terminal 2.
N to terminal 5.
Earth to
terminal.
Ensure shorting links are fitted between
terminals 1-2, 2-3, 4-5 and 5-6.
Ensure all screws are fully tightened.
Three Phase Connection (240/415V 3N ac 50Hz)
1
2
3
L1 L2 L3
Connect cable to terminal block:
Remove shorting links 1-2 and 2-3
L1, L2 and L3 to terminals 1, 2 and 3.
N to terminal 5.
Earth to
terminal.
Ensure shorting links are fitted between
terminals 4-5 and 5-6.
Ensure all screws are fully tightened.
3
4
5
6
N
Cable
Clamp
4
5
6
Shorting
N
Links
Cable
Clamp