Toshiba Satellite P205D Maintenance Manual page 27

Hide thumbs Also See for Satellite P205D:
Table of Contents

Advertisement

1.6 Batteries
1.6.1 Main Battery
Battery charging is controlled by a power supply microprocessor that is mounted on the
system board. The power supply microprocessor controls whether the charge is on or off and
detects a full charge when the AC adapter and battery are attached to the computer. The
system charges the battery using quick charge or trickle charge.
Quick Battery Charge
When the AC adapter is attached, there are two types of quick charges: quick charge
when the system is powered off and normal charge when the system is powered on.
The times required for charges are listed in the table below.
Normal charge (power on)
Quick charge (power off)
NOTES
1.
The time required for normal charge is affected by the amount of power the system
is consuming. Use of the fluorescent lamp and frequent disk access diverts power
and lengthens the charge time.
2.
Using quick charge, the power supply microprocessor automatically stops the
charge after eight hours regardless of the condition of the battery. Overcharging
could cause the battery to explode.
If any of the following occurs, the battery quick charge process stops.
1. The battery becomes fully charged.
2. The AC adapter or battery is removed.
3. The battery or output voltage is abnormal.
4. The battery temperature is abnormal.
5. The battery SMBus communication fails.
6. The battery cell is bad.
Detection of full charge
A full charge is detected from the battery pack through SMBus when the battery is
charging.
Satellite P200D/P205D Series Maintenance Manual