APPENDIX 3 FIRMWARE SWITCHS (WSW)
Selector
No.
1
2
3
4
5
6
|
8
l
Selector 1:
The ECP mode enhances the normal bidirectional communications between the machine
and the connected PC for higher transmission speed.
l
Selector 2:
If the machine recognizes via the STB signal line that the connected PC is powered off, it will
turn the PC interface outputs Low to protect the PC from hazards that could be caused by
weak electric current accidentally flown from the machine.
This selector determines whether the machine should recover from the inactive PC interface
to normal interfacing state upon receipt of data from the PC.
l
Selector 3:
This selector sets the time length from when the machine detects the PC powered off until it
recognizes the detected state as power-off.
If selector 2 is set to "0," it is recommended that selector 3 be set to "1": otherwise, the
machine may mistakenly detect PC powered off.
l
Selector 5:
This selector determines whether or not the machine will escape from phase C when it
detects an RTC (Return to Control) in non-ECM mode or an RCP (Return to Control Partial
page) in ECM mode.
l
Selectors 6 through 8:
At the start of reception, if the machine detects the frequency of calling signals (Ci) specified
by selectors 1 through 4 of WSW14, it will start the ringer sounding. When doing so, the
machine may fail to detect the calling signals normally due to noises superimposed at the
time of reception. To prevent it, use selectors 6 through 8 of WSW36.
If the machine detects higher frequencies than the lower limit specified by these selectors, it
will regard them as noise and interpret that detecting state as being normal, allowing the
ringer to keep sounding (until the machine starts automatic reception of FAX data if in the
FAX mode, according to the preset number of ringers).
WSW36 (Function setting 14)
Function
ECP* mode
Recovery from inactive PC
interface
PC power-off recognition time
Not used.
Escape from phase C
Lower limit of frequency to be
ignored after detection of calling
signals (Ci)
ECP mode
Recovery from inactive PC interface
PC power-off recognition time
Escape from phase C
Lower limit of frequency to be ignored after detection of calling signals
(Ci)
Setting and Specifications
0: ON
0: Disabled
0: Normal
0: Yes
No. 6 7 8
0 0 0 : 0 (Not ignored)
0 0 1 : 4 (448 Hz)
0 1 0 : 8 (244 Hz)
0 1 1 : 12 (162 Hz)
1 0 0 : 16 (122 Hz)
1 0 1 : 20 (97 Hz)
1 1 0 : 24 (81 Hz)
1 1 1 : 28 (69 Hz)
*ECP (Enhanced Capabilities Port)
A-38
1:
OFF
1:
Enabled
1:
Long
1:
No