OIL BURNER CLEANING:
These are aeneral
instructions
for cleanina
an oil burner. For specifics.
consult the burner manufacturer's
instructions.
1. Make sure all electrical
power to the boiler / burner and the fuel supply to the burner are
shut off.
2.
With the swing door open, clean any soot accumulations
from the end of the burner and
if applicable
burner head.
3. Remove the burner drawer assembly,
clean the electrodes
and then reset the electrode
spark gap per the manufacturer's
recommendations.
Refer back to the section in this
manual on OPERATING
THE BOILER - Nozzles and Electrodes.
4. Replace
the oil nozzle with the exact same size and type recommended
for use on
this boiler.
5. Reinstall the burner drawer assembly making sure the head location (and size if applicable)
are per the manufacturer's
recommendations.
If the burner being used has a damaged
head, replace the head with the exact same head recommended
for use on this boiler.
6. Inspect and clean the oil burner blower wheel.
7. Remove the oil pump cover and clean / replace the pump screen. Carefully
reassemble
ensuring
the pump cover makes a proper seal.
8. Securely
fasten the swing door shut.
9. Replace the fuel filter (if applicable).
10. Reconnect
the electrical
and fuel supplies.
11. Fire the burner, checking
for proper combustion
using combustion
test equipment
and
making adjustments
as necessary.
Refer to the section in this manual on OPERATING
THE BOILER - Final BurnerAdjustments.
12. Insure that all safety controls and operating
controls are functioning
properly.