Burner Settings Tables - Dunkirk Excelsior EXB Series Supplemental Instructions

Direct vent high efficiency oil-fired hot water boiler
Hide thumbs Also See for Excelsior EXB Series:
Table of Contents

Advertisement

TABLE 1: THE HIGH EFFICIENCY OIL BOILER IS CERTIFIED FOR USE ONLY WITH THE FOLLOWING PART
Items with Boiler
Burner
Options
Item
Riello
4-7/8" to 4" Appli-
40BF
ance Adapter
Beckett
NX
Boiler
Head
Insertion
Model
Type
Depth
4075
6 Slot
2.5"
4095
6 Slot
2.5"
5100
6 Slot
2.5"
5115
6 Slot
2.5"
5135
6 Slot
2.5"
6130
9 Slot
2.5"
Timings
Pre-purge
15 seconds
Post-Purge
2 minutes
TABLE 2: BECKETT/ECR PART NUMBERS
Beckett
Boiler
Oil Burner
ECR Oil Burner
Model
Model
4075
NX70LC
4095
NX70LC
5100
NX70LC
5115
NX70LF
5135
NX70LF
6130
NX70LD

BURNER SETTINGS TABLES

Termination
Part Num-
Options
ber
STD Termi-
240007535
nal
36" Riser
TABLE 2: BECKETT DIRECT VENT PRELIMINARY BURNER SETTINGS
Firing
Combus-
Rate
tion liner
[GPH]
0.75
Oval
0.95
Oval
1.00
None
1.15
V5
1.35
V5
1.30
V6
Part Number
240007531
240009393
240007532
240009395
240009396
240007533
NUMBERS
Part Num-
Vent Length
ber
Options
4" ID x 10
28972
FT
4" ID x 15
29231
FT
4" ID x 20
FT
*Includes Terminal Adapter and Caulking p/n 240006914
Pump
Nozzle
Nozzle
Pressure
Mfr.
Type
[PSI]
Delavan
0.60x60B
Hago
0.75x60B
Delavan
0.75x45B
Hago
1.00x60B
Delevan 1.10x60B
Danfoss
1.00x45B
10
Part number
Field Supplied Items
4x3" Single wall Reducer
240006909*
for Riello
240006910*
Single Wall Vent 25 FT Max
With Up To (8) 90 Deg.
Elbows for Air Intake Pipe
240006911*
Pressure
Air
Switch
Setting
Setpoint
150
1.5
0.65" WC
155
4.0
0.65" WC
175
4.0
0.85" WC
140
1.8
0.85" WC
150
2.5
0.85" WC
175
2.0
0.65" WC
P/N 240009355, Rev. C [11/15/2015]
Rated
AFUE
Efficiency
[%]
86.0
85.0
86.5
85.0
84.0
86.5

Advertisement