Eiki LC-HDT700 Owner's Manual page 79

Multimedia projector
Hide thumbs Also See for LC-HDT700:
Table of Contents

Advertisement

– Filter is out of scroll. Replace the filter cartridge with a new one promptly. (See
appears on the screen
– Adjust the focus of the projector.
– Check Projection Lens to see if it needs cleaning.
The image is out of
focus .
– Projecting from excessive slant angle to the screen may cause keystone distortion
– Check if Contrast or Brightness is adjusted properly. (See pages 40, 48)
– Check if Image level is selected properly. (See pages 39, 47)
The image is not
– Check the Lamp control function. ( See "Setting" section on page 61)
bright enough .
– Check the LAMP REPLACE indicator. If it lights, the end of lamp life is approaching.
– Check the Input signal, color system, video system, or computer system mode.
The color is strange .
– Adjust the Image Level properly. (See pages 40, 47)
The image is Left/
– Check the Ceiling / Rear function. (See pages 45, 52)
Right reversed .
The image is Top/
– Check the Ceiling function. (See pages 45, 52)
Bottom reversed .
The image is distorted
– Check PC adjust Menu or Screen Menu and adjust them.
or runs off .
Auto PC adjustment
– Check the Input signal. Auto PC Adjustment function cannot work when 480p, 575p,
function does not
work.
Some displays are
not seen during the
– Check the Display function. (see page 54)
operation .
The setting does not
– Make sure you selected Store after adjusting settings. Some settings cannot be
remain after turning
off power .
Power management
– Power management function cannot work while Freeze function is running or the
function does not
work .
Image disappears
– Check the power management function in the Setting. The power management is set
automatically .
– Check the connection to see if there is signal.
Capture function does
– Capture function is not available when the Picture in Picture function is set to User1-
not work .
Some menus cannot
– Each of the Video Input and Computer Input has a limit on selectable menus.
be selected .
The shutter does not
work .
pages 72-73)
Note: Moving the projector from a cool temperature location to a warm temperature
location may result in moisture condensation on Projection Lens. In such
cases, leave the projector OFF and wait until condensation evaporates.
and partial imperfect focus.
Replace the lamp with a new one promptly. (See page 74)
720p, 480i, 575i, 1035i, 1080i or 1080p is selected or when the digital signal is input
into HDMI or DVI-D terminal. See page 36.
stored if not registered with Store function.
shutter is closed.
to On at the factory.
5.
– Check "Protection" or "Release key" of the Shutter function. (See p.67)
Appendix
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents