● C2010
Check whether RF Connector (CON2002) is good or not.
CON2002 needs to be reworked if improper power, no power or
lower power than that on the golden sample, is measured on C2010.
The following figure is an example of C2010 signal measurement on
the spectrum analyzer.
● L2003
Check whether SAW filter (U2005) is good or not. U2005 needs to
be reworked if improper power, no power or lower power than that on
the golden sample, is measured on L2003. The following figure is an
example of L2003 signal measurement on the spectrum analyzer.
華
碩
電
腦
華
碩
電
腦
GTC ■ Service Manual
98