IV . POWER SUPPLY
Figure 2-401 is a diagram of the machine's power supply system.
The machine is supplied with two channels of 24 V power: one (J4-1 input) is sent to loads
through a fuse (FU1), while the other (J1-6 input) is sent to sensors and the ADF controller PCB after
conversion by a regulator (Q28) to 5 V power.
The fuse (FU1) is used to cut the line to protect the circuit in response to overcurrent.
Copier
COPYRIGHT © 1999 CANON INC.
J4
24V
1
FU1
J1
FU2
24V
Regulator
6
ADF controller PCB
Figure 2-401
CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 2 OPERATIONS
24R
5V
5R
Q28
• Motor
• Clutch
• Solenoid
• Sensor