17. Adjustments and settings
CH anti cycling delay setting :
If you would like to change the setting of CH anti cycling delay, if you want 3 min, proceed as follows:
(N
: T
OTE
HE FACTORY SETTING IS
1
Switch to installer mode, press button
and
for 5 seconds, the
display shows :10=0 if there is no
default in the default register.
2
Press 3 times on menu button
gain access to menu 4, the display
shows : 40=0 or 40=1
3
Change to section 8 (CH anti cycling
delay), press on button
the display shows :48=2.5 (factory
setting 2 min 30 seconds)
4 = menu 4
8 = section 8
2.5 = 2.5 min (2 min 30 seconds)
4
Press the setting button
time, the 3rd and 4th digits flash
together, Then press the
change the CH anti cycling delay, the
display shows :
48=3.0 press the setting button
to confirm the value. The display
stops flashing.
Setting procedure is finished.
To exit from setting mode, leave the
boiler for approx. 1 minute then the
PCB will switch back to user mode.
After programming please close the
front control panel cover P (Fig. 43
page 36)
42
2
30
MIN
SECONDS AND THE FOLLOWING EXPLANATION REFER TO MENU
1
2
to
3
8 times,
4
one
to
(continued)
5 "
x 8
4
8)
SECTION
Display
x 3